Contents: 30 liter (20-50 m²)
Visble effect Facade Impregnation: ca 10 year.
Shelf life: minimum 24 months
Property profile Facade Impregnation
- For hydrophobizing impregnation of porous, cementitious building materials such as brick and clinker masonry work, fair-faced sand-lime brick masonry work, cementitious renders, fibrated cement, aerated concrete, light-weight concrete and modular concrete blocks, natural stone. Can also be used on surfaces already hydrophobized.
- Reduces energy loss
- Alternative to Funcosil SNL
Directions for application of Facade Impregnation
The Facade Impregnation is applied under gravity in a flow coating procedure generously enough that a 30-50 cm long film of liquid runs down the building material. The nozzle should be held horizontally and led along the facade without interruption. After the Facade Impregnation has been absorbed, the process is repeated several times. Spraying pressure and nozzle diameter should be selected so that misting does not occur. To avoid missing areas, limited sections should be completely impregnated without interruption. A brush or roller can be used for smaller, complicated surfaces that do not allow a spray application. In this case, the required application rate can only be achieved by working with well saturated tools. Protect the freshly impregnated surface from driving rain for at least 5 hours. Strong wind and sunlight may accelerate evaporation of the carrier which has a negative influence on penetration depth. The surface of less absorbent substrates should be washed off with V 101 Thinner half an hour to an hour after application to remove excess material which could create a gloss.
Working temperature: Water repelling impregnation is preferably carried out at temperatures between +10 °C and +25 °C. Sun awnings can be used to prevent surfaces from heating too strongly. At temperatures below 10 °C, evaporation of the carrier and formation of the active ingredient may be considerably delayed.
Application rate Facade Impregnation
Brickwork, fine-pored: min. 1.0 l/m²
Brickwork, large-pored: min. 1.2 l/m²
Sand/lime brick, smooth: min. 0.6 l/m²
Sand/lime brick, natural split, bossed: min. 0.9 l/m²
Render: min. 0.6 l/m²
Porous concrete: min. 1.2 l/m²
Fibre cement: min. 0.4 l/m²
Modular concrete blocks: min. 1.5 l/m²
Natural stone, fine-pored: min. 0.8 l/m²
Natural stone, large-pored: min. 1.8 l/m²
Apply to a large enough trial surface (1-2 m²) to determine the precise amount of impregnation agent required.